Search on this blog

Search on this blog

implant_library

implant_library

is constantly updated

You will be redirected to our cloud server to download our implant library.

  • Save all files or all required implant systems to your computer.
  • The download may take a few minutes.
  • Unzip the zip file
  • Place the extracted folder in C:\Program Files\PROMADENT\Biss [current version]\implants
  • Restart BISS

 

Have fun! 🙂

Note: Some of the products shown in the software within the entire implant library may not be approved for all countries.

Expand your implant library independently?

No problem, with our step-by-step instructions

Facts and prerequisites

  • Allowed file formats are .stl, .ply and .obj
  • Only 2-3 files are needed -> Scanbody, Analog [and possibly a symmetry.txt file]
  • The file for the scan body requires an outward-pointing normal.
  • The file for the analog requires the outer casing of the analog. Additionally, it needs at least one hole facing upwards, towards the scanbody. For a hole for a Basal screw, the data set also needs a hole facing downwards.
  • The scanbody and analog must be aligned along a coordinate axis in a common coordinate system (which axis [x, y, z] doesn’t matter, Biss will figure that out automatically)
  • You can check the files in the MeshLab program. The analog has a light area inside, and the scanbody has a light area outside.

Instructions - Variant 1

1. Go to C:\Program
Files\PROMADENT\Biss [current version]\implants

2. Create subfolders as needed, e.g., sorted by manufacturer and diameter. IMPORTANT: Each implant geometry requires a separate folder, each containing only the 2-3 files listed above.

3. Add the 2-3 files to the created folder. To ensure the files are recognized, rename the analog data set to “[…]_analog” and the scanbody data set to “[…]_scanbody”.

csm_Implantate_4_5a706adee3

4. When you reopen BiSS, you will find the inserted folders in the “Implants” step on the left under “System-wide”.

Instructions - Variant 2

csm_Implantate_1.1_eea682364a

1. Go to C:\Users\[current user]\.config\biss. Create a new folder here named “implants”.

csm_Implantate_2.1_2b23a5ba8d

2. Create subfolders as needed, e.g., sorted by manufacturer and diameter. IMPORTANT: Each implant geometry requires a separate folder, each containing only the 2-3 files listed above.

3. Add the 2-3 files to the created folder. To ensure the files are recognized, rename the analog data set to “[…]_analog” and the scanbody data set to “[…]_scanbody”.

csm_Implantate_4.1_b5c50f0527

4. When you reopen BiSS, you will find the inserted folders in the “Implants” step on the left under “User-specific”.

Address

Im Nordfeld 13, 29336 Nienhagen, Germany

Contact

T: +49 (0) 5144 / 6980-200
E-Mail: info@promadent.de